Cabling audit and certification: finding out whether the cable is to blame

When the network of a company or a public body performs badly, the visible parts get replaced first: the switch, the Wi-Fi access points, sometimes the carrier. If the fault is in the cable, nothing changes, and the budget is spent. Measuring the cabling generally costs less than the hardware about to be replaced, and tells you whether the cable is to blame.

Send the address and the number of outlets to contact@gpc-reseaux.com: we will price the audit. Or call +33 4 28 29 05 16.

Signs that point to the cabling

  • A workstation is stuck at 100 Mbit/s on gigabit equipment: most often a broken or badly terminated pair, once the patch cord and network card have been ruled out.
  • A Wi-Fi access point, camera or phone powered over the cable reboots for no reason: link too long, damaged connectors, cable unsuited to the power required.
  • The same outlets cause problems whatever device is plugged in.
  • Errors build up on certain switch ports; IP telephony suffers brief dropouts.
  • The problem appeared after building works, a refit or the addition of outlets.
  • Nobody knows which outlet corresponds to which port: no numbering, no drawings.

Testing is not certifying

A continuity tester checks that the eight wires are connected in the right order. It says nothing about speed. A qualification tester checks that a given speed gets through, without ruling on the standard.

A certifier measures the link over the whole frequency range of its class (up to 500 MHz for Class EA, Category 6A cabling): insertion loss, crosstalk, return loss, length. It compares the results with the limits of the standard and gives a verdict for each link. When a link fails, it usually locates the fault: you know whether a connector needs redoing or the cable needs replacing.

What an audit includes

  • a survey and numbering of the links, rack and outlets;
  • certification of every copper link, and measurement of the fibre links where there are any (insertion loss and OTDR);
  • a check of the patch cords;
  • a condition report on the rack: patching, power supply, earthing, free space;
  • a report a non-specialist can read: what is compliant, what can be repaired, what must be replaced, with a price for the remedial work.

When to ask for one

  • before renewing switches or moving to faster Wi-Fi access points;
  • before signing a lease or moving into premises that are already cabled;
  • after incidents that keep recurring without explanation;
  • at handover of works delivered without test reports;
  • when you take over a site for which nobody has the drawings.

What we find most often

Connectors to redo, cables pinched or bent too tightly in a ceiling void, links that are too long, cables split to serve two outlets, worn patch cords. Most of it can be fixed without re-cabling everything.


GPC Réseaux carries out audits and certification of copper and fibre cabling in Lyon and across Auvergne-Rhône-Alpes, for businesses, public bodies and their IT service providers. contact@gpc-reseaux.com or +33 4 28 29 05 16.

Request a quotation

The information you enter is used by GPC Réseaux solely to respond to your enquiry and prepare a quotation. Find out more: privacy policy.

✉️ Email us 📝 Free quotation